omni
asha

Items per page:
12 Companies with Results for electrode 1 - 10 of 12

Freedom Stim Electrodes

3477 Creek Circle Guntersville, AL 35976 Tel: 601-968-0981

View company website

The Freedom Stim™ line of dysphagia electrodes are high-quality, low-impedance electrodes that are compatible with ...

Glottal Enterprises, Inc.

1201 E. Fayette St. Syracuse, NY 13210 Tel: 315-422-1213

View company website
2 More Results

Glottal

... the EG2-PCX2 enables it to indicate proper electrode placement and provide a quantitative indication of vertical ... connection to a personal computer. The dual-channel electrodes for the EG2-PCX2 measure the translaryngeal electrical ...

Glottal

... Aeroview Waveview Dual View Electroglottography EG2-PCX2 PhaseComp Electrodes Sub Glottal Pressure Measurement Systems PG 100E PG ...

close more results

Glottal Enterprises helps speech, voice, and singing research community with proven voice and speech measurement ...

Otodynamics Ltd.

30 - 38 Beaconsfield Road Herts Tel: 704-450-8444

View company website
6 More Results

Otoport OAE+ABR Lite Model : Product Information

... test physiological and powerline noise analysis - Individual three electrode impedance analysis - Intelligent powerline interference rejection - ABR confirmation ...

Otoport OAE+ABR Upgrade : Accessories

... information (opens in a new tab/window). ABR Electrode Cables ABR Electrode Cables 1m Product code: A18-20-1-0 Order code: ABR-EC1 ABR Electrode Cables 2m Product code: A18-20-2-0 ...

Otoport DP+TE OAE+ABR : Product Information

... screen Monitors powerline interference and infant noise. Individual electrodes are highlighted if their impedance is too high, ... ABR supplied with: UGD probe, 1m and 2m electrode cables, manuals, consumables starter pack (including pack of ...

Otoport OAE+ABR Lite Model : Consumables

... information (opens in a new tab/window). ABR Electrodes ABR Consumables Starter Pack Product code: A18-21- ...

Otoport OAE+ABR Upgrade : Product Information

... screen Monitors powerline interference and infant noise. Individual electrodes are highlighted if their impedance is too high, ...

Otoport OAE+ABR Upgrade : Consumables

... information (opens in a new tab/window). ABR Electrodes ABR Consumables Starter Pack Product code: A18-21- ...

close more results

... test physiological and powerline noise analysis - Individual three electrode impedance analysis - Intelligent powerline interference rejection - ABR confirmation ...

Oticon Medical, LLC

580 Howard Ave Somerset, NJ 08873 Tel: 732-560-0727

View company website
5 More Results

Hearing with a cochlear implant | Oticon Medical

... on the temporal bone. The receiver has an electrode array that is placed in the cochlea. 1. ... electronic signal sent to the cochlea. 4. The electrode array is inserted in the cochlea. Each electrode ...

Child treatment process | Oticon Medical

... check whether it is possible to insert an electrode array into the cochlea. In some cases, this ... the receiver containing the electronic circuits. Next, the electrode array is carefully inserted into the cochlea. Implant ...

Cochlear implantation step by step | Oticon Medical

... Next, the implant receiver is attached and the electrode array is carefully inserted into the cochlea. Before ... your hearing needs, and the settings for each electrode are adjusted to make hearing clear and comfortable. ...

Cochlear Implant Users | Oticon Medical

... an electronic signal and sends it to an electrode array inserted in the cochlea. 4. Each electrode on the array corresponds to a signal frequency ...

Neuro Zti | Compact & robust | Oticon Medical

... the extensive risk of healing complications. Two different electrode arrays can be used with the Neuro Zti. ...

close more results

... on the temporal bone. The receiver has an electrode array that is placed in the cochlea. 1. ... electronic signal sent to the cochlea. 4. The electrode array is inserted in the cochlea. Each electrode ...

Oaktree Products, Inc.

716 Crown Industrial Ct Chesterfield, MO 63005 Tel: 636-530-1664 x 7001

View company website

... of clinical supplies to the hearing care industry Electrodes & Supplies Electrodes Supplies

Maico Diagnostics

7625 Golden Triangle Drive Eden Prairie, MN 55344

View company website
3 More Results

easyScreen

... 72 dB CMRR >110 dB at 100 Hz Electrode Cables 3 electrode cables (black, yellow and white) TEOAE Level TEOAE ... easyScreen Charging cradle Power supply USB cable Preamplifier Electrode lead wires Carrying case Starter kit Cleaning cloth ...

MB 11 BERAphone

... 90% Speaker BERAphone®: integrated, dynamic wideband speaker (8Ω) Electrodes BERAphone®: reusable, stainless steel electrodes with gel protectors. Preamplifier Integrated, 87 dB amplification ( ...

MB 11 Classic

... C (+41 to +122°F); Maximum humidity 90% Electrodes Disposable snap Preamplifier Integrated, 87 dB amplification (23, ...

close more results

... 72 dB CMRR >110 dB at 100 Hz Electrode Cables 3 electrode cables (black, yellow and white) TEOAE Level TEOAE ... easyScreen Charging cradle Power supply USB cable Preamplifier Electrode lead wires Carrying case Starter kit Cleaning cloth ...

Clarke Schools for Hearing and Speech

45 Round Hill Rd Northampton, MA 01060 Tel: 413-584-3450

View company website

... of two parts: an internal device that has electrodes that are surgically implanted in the cochlea; and, ...

Sanibel Supply

7625 Golden Triangle Drive Eden Prairie, MN 55344 952-428-6322

Hi-Dow Professional

6151 Mcleod Dr Las Vegas, MO 89120 702-467-1525

Gordon N Stowe & Associates

586 Palwaukee Dr Wheeling, IL 60090 847-459-1770